Sigma -V series servo motor SGMSV.
Rated output: 2.0kw.
Power supply voltage: AC400V.
Serial encoder: 20 bit Delta (standard).
Design sequence: standard.
Shaft end: straight shaft, without keyway (standard).
Optional: with oil seal.
Super power rate.
Variety is complete (1.0kW ~ 7.0kW, with hold brake) .
Equipped with a high resolution serial encoder (20 bit) SGMCS-2ZN3A31.
Standard using IP67 (7.0kw for IP22)
SGMCS-2ZN3A31
Use example:
Placement machine.
Punch printed circuit board.
Machine tool feeding device.
Rating and specifications:
Rated time: continuous.
Vibration level: V15.
Insulation resistance: DC500V, 10M, or above.
Using ambient temperature: 0 ~ 40 degrees C.
Excitation mode: permanent magnet type SGMCS-2ZN3A31.
Installation method: flange type .
Heat resistance grade: F.
Insulation withstand voltage: AC1500V 1 minutes (200V), AC1800V 1 minutes (400V).
Protection mode: fully enclosed self cooling type IP67 (except shaft through part).
The use of environmental humidity: 20 ~ 80% (not dew).
Connection mode: direct connection.
Rotation direction: clockwise direction (CCW) rotation at the load side under the direction of rotationSecurity module SGMCS-2ZN3A31.
Maximum applicable motor capacity: 1.0kw.
Power supply voltage: three phase AC400V.
Interface: MECHATROLINK- III communication command type (rotary servo motor).
Design sequence: A.
Hardware specification: dynamic brake (DB).
Matching (software): no matching (standard).
Matching (parameters): no matching (standard).
Optional module: security module.
European EC standards: Based on the integration of mechanical instructions standard ISO13849-1 EN,
Security module with individual standard 61800-5-2 IEC specified security function.
Through the combination of the SGDV servo unit, the best safety design of the mechanical system is realized.
Suitable for AC servo drive, with the following safety features specified in the international standard IEC61800-5-2 (Japan''s first).
Can easily achievee the best security dessign of mechanical systems SGMCS-2ZN3A31.
Torque Off Safe (STO)
Stop Safe 1 (SS1)
Stop Safe 2 (SS2)
Limited Speed Safely (SLS)
Equipped with 2 security functions, can be set (distribution) security functions.
In addition, the monitoring time and other itemms can be changed through the parameter SGMCS-2ZN3A31.
With the use of the servo unit with a security module, so that the system can be simplified and miniaturized.
SGMCS-2ZN3A31 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGMCS-2ZN3A31&select=5