QJ71FL71-T-F01 The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet MITSUBISHI QJ71FL71-T-F01 FL-net module


1ch RS-232.
1ch RS-422/485.
Basic language programming module.
The position signal of the first axis servo amplifier, which is used on the motion CPU, is used as a trigger,
Starting from the programmable controller CPU to the second axis servo amplifier,
Time to output speed command of servo amplifier QJ71FL71-T-F01.
This time is the index of data ttransmission speed between CPU.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time QJ71FL71-T-F01.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias QJ71FL71-T-F01.
Output points: 4 points (select the source type + drain type), 2 points (select the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI QJ71FL71-T-F01.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI QJ71FL71-T-F01.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures MITSUBISHI QJ71FL71-T-F01.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down.
FL-net (OPCN-2) Ver.2.00 interface.
10BASE5/10BASE-T use.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet.
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cabble, the straight line and the cross line can be used QJ71FL71-T-F01.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.