OMRON C200HW-COM04-V1 Communications Board OMRON C200HW-COM04-V1


I/O Interface UnitName: CS1D Processcontrol CPU Unit.
Specifications: CPU section,
Equivalent to the CS1D-CPU65H;
Loop control section,
LCB05D Operation method:
Function block method,
Number of function blocks:
500 blocks max.
Minimum operation cycle:
100 ms PID control method:
PID with two degrees of freedom,
(with autotuning function);
Current consumption: 5 V system, 1 C200HW-COM04-V1.04A;
26 V system, --.
Standards: UC1, N, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables C200HW-COM04-V1.
Model: C200HW-COM04-V1.
Specifications: Communications port for the Controller Link, SYSMAC LINK Units, one RS-232C port, and a protocol macro function.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit C200HW-COM04-V1.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON C200HW-COM04-V1.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON C200HW-COM04-V1.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON C200HW-COM04-V1.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C200HW-COM04-V1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.