LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
MITSUBISHI FX3SA-20MR-CM PLC FX3SA-20MR-CM


MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption FX3SA-20MR-CM.
DC24V external power suppply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time FX3SA-20MR-CM.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation FX3SA-20MR-CM.
Can reduce the power consumption in the stop. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.
Input and output points: 20 points MITSUBISHI FX3SA-20MR-CM.
Power supply: AC100-240V.
Input points: 12 points.
Output points: 8 points.
Output form: relay output.
Power consumption: 20W.
Weight: 0.4KG.
Outline dimension: 75x90x75mm.
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model MITSUBISHI FX3SA-20MR-CM.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc MITSUBISHI FX3SA-20MR-CM.. Power: 185kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Length: 15 meters.
Cable manufacturing specifications.
When there is no connection options, according to the table under the cable.<
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder FX3SA-20MR-CM. "Convert connectors to fast connectors.
According to the location of the connection equipment distribution module.

Related supply information