LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
CVM1-BC103 CPU Backplane OMRON CVM1-BC103


Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CVM1-BC103.
Bit-level I/OO distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CVM1-BC103.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. NO. OF I/O SLOTS: 11 SLOTS
NO. OF I/O SLOTS: 10 SLOTSProduct name: CS1 CPU Backplane CVM1-BC103.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 5 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No OMRON CVM1-BC103.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control OMRON CVM1-BC103. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V OMRON CVM1-BC103.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CVM1-BC103.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information