LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
CV500-RM221 OMRON CV500-RM221 Remote I/O Master Unit


CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 12; Output, 8 CV500-RM221.
Standards: UC1, N, L, CE.
High Performing Programmaable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port CV500-RM221.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. CPU Unit: CP1L-M CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 24; Output, 16 CV500-RM221.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port OMRON CV500-RM221.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams.
CV500-RM SYSMAC BUS Remote I/O Master Unit Wired CV500-RM221 OMRON CV500-RM221.
Wire Type.Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON CV500-RM221.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansiion I/O Racks: 3 Racks CV500-RM221.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.C500-OA I/O Unit Triac Output 16 pts C500-OA222(3G2A5-OA222).
AC132V 1A.