LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
CS1W-AD161 Analog I/O Unit OMRON CS1W-AD161


Product name: E@@S type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0 CS1W-AD161.17A; 24 V,0.07A.
Standards: CE.
The CP1E Programmable Controoller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CS1W-AD161.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Output method: Transistor sinking.
Inputs: ---.
Outputs: 16.
Unit type: CS-series Special I/O Units.
Product name: Analog Input Units CS1W-AD161.
Specifications: I/O points, 16 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max OMRON CS1W-AD161.
(Settable to 1 ms/point).
Externa connection, MIL connector.
Current consumption: 5V, 0.15A; 26V, 0.06A.
Standards: UC1, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals OMRON CS1W-AD161. Name: Temperature Control Module.
Model: C200H-TC003.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Current output.Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; PNP; -- OMRON CS1W-AD161.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Hostt Link Module CS1W-AD161.
Model: C200H-LK201-V1.
Communication ports: 1 RS-232C, 25 pin female.Model: C500-AE001(3G2A5-AE001).
Output line driver converts the input open-collector output incremental encoder form, taking the position control unit.

Related supply information