LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
CS1W-MCH71 OMRON CS1W-MCH71


Name: Heat/Cool Temperature Control Module.
Model: C200H-TV001.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Transistor output.Model : C500-PS223.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.
Unit type: CS1 CPU Bus Unit CS1W-MCH71.
Product Name: MECHATROLINK-II,
compatible Motion Controol Unit.
Specifications: Control modes: Position,
speed, or torque control via MECHSTROLINK-II,
Control axes: 32 axes max.
(30 physical axes, 2 virtual axes) CS1W-MCH71.
Internal programming language: Special,
motion control language.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.80A; 26V, --.
Standards: UC1, CE.
Improve Equipment Design Efficiency and,
Shorten Tact Time CS1W-MCH71.
Control Servos for up to 16 axes in a,
motion network with one Position Control,
Unit that supports MECHATROLINK-II .
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Product name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 3 slots OMRON CS1W-MCH71.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No OMRON CS1W-MCH71.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control OMRON CS1W-MCH71. Model : C500-PS223-E.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.Output method: Relay.
Inputs: 12.
Outputs: 8.Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1W-MCH71.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Related supply information