CRT1-MD16 OMRON CRT1-MD16


Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/8 inputs CRT1-MD16.
Externa connection: Removable erminal block.
No. of unit numberss allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CRT1-MD16.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CRT1-MD16.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON CRT1-MD16.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring OMRON CRT1-MD16.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units OMRON CRT1-MD16.
Specifications: I/O points, 8 inputs;
Input voltage and current: 12 to 24 VDC, 10 mA;
Commons, Independent contacts; External connection,
Removable terminal block; No. of words allocated, 1 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Name: Two-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CRT1-MD16.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.