LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
C200HG-CPU63-E Max noof con-necting Expansion I/O Racks: 3 Racks OMRON C200HG-CPU63-E


Number of inputs: 8 pts.
Input Voltage: 200 to 240VAC.
Input Current: 6 mA.Model: C200H-IM211.
No. of inputs: 8 pts.
Input voltage: 12 to 24 VAC/DC, +10%/–15%.
Input current: 10mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks C200HG-CPU63-E.
Inputs percom-mon: 8 ptss.
Internal currentcon-sump-tion:
UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ C200HG-CPU63-E.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.CPU Unit: CP1L-L CPU Units with 14 Points C200HG-CPU63-E.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 8; Output, 6.
Standards: UC1, N, L, CE OMRON C200HG-CPU63-E.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams OMRON C200HG-CPU63-E. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON C200HG-CPU63-E.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C200HG-CPU63-E.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Related supply information