LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON K3HB-VLC-CPBC11 Communications Manual PDF
Product model: K3HB-VLC-CPBC11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three K3HB-VLC-CPBC11 PDF.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-VLC-CPBC11
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-VLC-CPBC11 PDF.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiriing length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-CPBC11 Manual. Error will occur in the operating,
values of the overload elements K3HB-VLC-CPBC11 PDF. It is recommended to test operation,
before using the K2CM. Detect errors in motors and other equipment,
through current changes.
Use in either overcurrent or undercurrent mode.
Monitor AC or DC currents with one Relay.
Use with commercially available CTs (CT secondary side: 0 to 1 A or 0 to 5 A) OMRON Communications Manual.
Settings for the operating value, hysteresis, startup lock time,
and operating time.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals) OMRON Communications Manual.
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment OMRON Communications Manual K3HB-VLC-CPBC11 Communications Manual.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resisstive load) K3HB-VLC-CPBC11 Manual.
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator.