LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON E5AN-R3H03T-FLK-N User's Manual PDF
Product model: E5AN-R3H03T-FLK-N
Name: Digital Temperature Controller E5AN-R3H03T-FLK-N User's Manual OMRON E5AN-R3H03T-FLK-N Manual
Brand: OMRON
Sort: User's Manual
File language: English
Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points E5AN-R3H03T-FLK-N PDF.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 E5AN-R3H03T-FLK-N
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices E5AN-R3H03T-FLK-N PDF.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design E5AN-R3H03T-FLK-N PDF.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise OMRON User's Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceeNet,
Communications Unit OMRON User's Manual E5AN-R3H03T-FLK-N Manual. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON User's Manual.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AN-R3H03T-FLK-N User's Manual.
Through the infrared port can be carried out from the frront of the communication E5AN-R3H03T-FLK-N Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products