Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover) E5AN-C303T-FLK-N PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E5AN-C303T-FLK-N
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10 E5AN-C303T-FLK-N PDF. 5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5AN-C303T-FLK-N PDF.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communicatioon conversion Village (sold separately) connected to the computer after,
No power connection can be set E5AN-C303T-FLK-N Manual.
It can be easily set by CS-Thermo (sold separately) OMRON INSTRUCTION Manual. Absolute diameter 65.
High resolution absolute type for detecting instrument and precision positioning.
To achieve a resolution of 12 bits (maximum 4096) of high resolution.
Response frequency is the high speed response of 40kHz
Output with gray code and BCD code.
The shape is smaller than the old one OMRON INSTRUCTION Manual.
Power supply voltage: DC5 ~ 24V.
Output form: BCD.
Output code: open collector output. Appearance: 4 dia.
Sensing distance: 1.2 mm.
Connecting method: M8 Pre-wired Connector Models (0.3 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NC.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output OMRON INSTRUCTION Manual.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequuency stably detects moving,
objects: 5 kHz max E5AN-C303T-FLK-N INSTRUCTION Manual.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) E5AN-C303T-FLK-N Manual.
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables.