Name: DC Power Supply Unit.
Power supply voltage: 24 VDC.
Output capacity: 5 VDC output capacity, 4.3A;
26 VDC output capacity, 0.56A;
Total, 28W.
Options: 24 V DC service power supply, No;
RUN output, No CS1H-CPU67H PDF.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.
NO. OF I/O SLOTS: 6 SLOTSModel: C500-CN531.
Cable length: 50 m
CS1H-CPU67H
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
1 axis, Pulse output. speeds: 1 to 100, 000 pps.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps CS1H-CPU67H PDF.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks)Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Line-driver output;
Number of control axes : 1 axis CS1H-CPU67H PDF.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines OMRON OPERATION MANUAL.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control. Provided with SYSMAAC LINK Unit CS1H-CPU67H Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V OMRON OPERATION MANUAL.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON OPERATION MANUAL.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CS1H-CPU67H OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1H-CPU67H Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.