Name: Controller Link Module.
Model: C200HW-CLK21.
Communications method: N: N token bus.
Code Manchester: codeModel: C200HW-COM04-V1.
Specifications: Communications port for the Controller Link, SYSMAC LINK Units, one RS-232C port, and a protocol macro function CS1G-CPU45-EV1 PDF. CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 100 VAC CV500-FHD01-EName: Screw Terminal Block with SSR Outputs
CS1G-CPU45-EV1
Specifications: Outputs;
8 outputs; SSR.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CS1G-CPU45-EV1 PDF.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1G-CPU45-EV1 PDF. Name: High-speed Counter Module.
Model: C200H-CT021.
Number of axes: 2 axis/Unit.
Operating modes: 7.
High-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sourrces CS1G-CPU45-EV1 Manual. Model: C200H-ID216 OMRON OPERATION MANUAL.
No. of points: 64 pts.
Specifications: 24VDC.
Weight: 180g max.Model : C500-LK009-V1.
Maximum of 32 PCs can be linked.Name: Analog I/O Slave Units.
Specifications: Analog inputs;
4 inputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON OPERATION MANUAL.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON OPERATION MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Provided with a 2-m cable for ladder programming.Name: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
8 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CS1G-CPU45-EV1 OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1G-CPU45-EV1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.