Model : CV1000-DM151.
Available CV1000/2000/CVM1-CPU21-V2.
128k words.Model: CPM2C-10CDTM-D. CPU Unit: Units with 10 I/O points.
2 MIL connectors.
Inputs: 6 inputs CS1G-CPU43-V1 PDF.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Model: C500-CN531.
Cable length: 50 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT
CS1G-CPU43-V1
Supply voltage: 24 VDC
Operating voltage range: 20.4 to 28.8 VDC
Power consumption: 100 W max.
Output capacity: 12 A, 5 VDCUnit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block CS1G-CPU43-V1 PDF.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications CS1G-CPU43-V1 PDF.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Model: C200H-BC051-V2 OMRON Installation Guide.
No. of I/O slots: 5 slots.Model: C200H-ME832.
Description: EEPROM, 8K words, battery back-up.with clock(CPU21, CPU23 only).C500-ID Special I/O Unit ID Sensor Unit For the C500-IDS22 C500-IDA22.C500-AS Special I/O Unit ASCII BASIC UNIT C500-ASC01.Power supply: AC power supply.
Output method: Transistor output sink type OMRON Installation Guide.
Inputs points: 12 points.
Outputs points: 8 points.Model: C200H-OC222N.
No. of points: 12 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit CS1G-CPU43-V1 Manual.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1 OMRON Installation Guide. 25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CS1G-CPU43-V1 Installation Guide.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1G-CPU43-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.