LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON K3HB-VLC-FLK1BT11 AC100-240 datasheet PDF
Product model: K3HB-VLC-FLK1BT11 AC100-240
Name: Load sensor, mV instrument
Brand: OMRON
Sort: PDF datasheet
File language: English
Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt K3HB-VLC-FLK1BT11 AC100-240 PDF.
Action time: time limit element time to adjust the degree 0 K3HB-VLC-FLK1BT11 AC100-24025-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0 K3HB-VLC-FLK1BT11 AC100-240 PDF. 1 1000.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type K3HB-VLC-FLK1BT11 AC100-240 PDF.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination between OCR and MCCB is simple.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display of the accident occurrence phase is used to facilitate the inspection after the accident.
Reduce the consumption of VA, reduce the burden of converter. Input type: DC current input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simmulation, measurement and display, identification of the panel table K3HB-VLC-FLK1BT11 AC100-240 datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the opperation trend K3HB-VLC-FLK1BT11 AC100-240 datasheet.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Depth (panel
Related products