LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON K3HB-PNB-FLK3AT11 AC100-240 datasheet PDF
Product model: K3HB-PNB-FLK3AT11 AC100-240
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
Type of input: AC voltage input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-PNB-FLK3AT11 AC100-240 PDF.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PNB-FLK3AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DevCategory: external supply 100mA DC5V type K3HB-PNB-FLK3AT11 AC100-240 PDF.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-PNB-FLK3AT11 AC100-240 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is inddicated from the start of operation K3HB-PNB-FLK3AT11 AC100-240 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-PNB-FLK3AT11 AC100-240 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products