OMRON K3HB-PPB-L1AT11 AC/DC24V datasheet PDF
Product model: K3HB-PPB-L1AT11 AC/DC24V
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: DC voltage input type.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-PPB-L1AT11 AC/DC24V PDF.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PPB-L1AT11 AC/DC24V
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations K3HB-PPB-L1AT11 AC/DC24V PDF.
DevType of input: AC voltage input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PPB-L1AT11 AC/DC24V PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Depth (panelStandard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shuntt,
Easy to coordinate digital VR K3HB-PPB-L1AT11 AC/DC24V datasheet.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of tthe experimental switch can be easily recognized K3HB-PPB-L1AT11 AC/DC24V datasheet.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except).
Related products
OMRON
Time interval table
K3HB-PPB-L1AT11 AC100-240
OMRON Time interval table K3HB-PPB-L1AT11 AC100-240
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PPB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-FLK3AT11 AC/DC24V
Input type: PNP input type. Event input
OMRON
Rotating pulse meter
K3HB-RNB-L2AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-L2AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK1AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ