OMRON K3HB-RPB-L2AT11 AC/DC24V datasheet PDF
Product model: K3HB-RPB-L2AT11 AC/DC24V
Name: Rotating pulse meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Ideal for water level control.
Sensitivity adjustment and timer for easy usage.
Sensitivity adjustment from 10 k to 100 kΩ.
Enables easy onsite adjustment.
ON-delay timer from 0.1 to 10 s.
Ideal as countermeasure for waves on liquid surfaces.
Width of 17.5 mm to reduce space required in panels K3HB-RPB-L2AT11 AC/DC24V PDF.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires K3HB-RPB-L2AT11 AC/DC24V
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models with transistor outputs added for low contact wear. Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V K3HB-RPB-L2AT11 AC/DC24V PDF.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement K3HB-RPB-L2AT11 AC/DC24V PDF.
Can carry on the high speed spinPower supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-RPB-L2AT11 AC/DC24V datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-RPB-L2AT11 AC/DC24V datasheet.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Time interval table
K3HB-PNB-L2AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-L2AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PPB-L2AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-L2AT11 AC/DC24V
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PPB-AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-AT11 AC/DC24V
Input type: PNP input type. Event input