Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CZ-R2MLD PDF.
Ideal for the thermal input devices of Temperature Controllers
E5CZ-R2MLD
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 20cm E5CZ-R2MLD PDF.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CZ-R2MLD PDF. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: E5AZ-R3 + E53-AZM .
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: current.
Input: thermocouple.
New generation intelligent general temperature controller.
The thickness is only 78 mm E5CZ-R2MLD datasheet.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed E5CZ-R2MLD datasheet.
Can use heating or heating / cooling control.
Event entry allows multiple SP options and run / stop functions.