Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CRT1-ID16-B PDF.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
CRT1-ID16-B
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Power supply: DC power supply CRT1-ID16-B PDF.
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.For 10-slot Backplane.Number of inputs: 8 pts.
Input Voltage: 12 to 24V DC.
Input Current: 10 mA.Name: Temperature Control Module.
Model: C200H-TC101.
Sensor: Platinum resistance thermometer: JPt100 Pt100 CRT1-ID16-B PDF.
Control output: Transistor output.For 5-slot Backplane.CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223.
4-MB memory; w/floating-point processor.Specification: Thermocouple inputt (J/K),
ON/OFF or advanced PID control,
transistor (PNP) output, 2 loops CRT1-ID16-B Manual. Name: Three-tier Screw Terminal Block OMRON UL Standards and CSA Standards.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON UL Standards and CSA Standards.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON UL Standards and CSA Standards. Name: Bit Slave Units with e-CON Connectors.
Specifications: Inputs; 2 inputs; NPN.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied ffrom the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection CRT1-ID16-B UL Standards and CSA Standards.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits CRT1-ID16-B Manual.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.