MITSUBISHI Q25HCPU Programming Manual (MELSAP-L) PDF
Product model: Q25HCPU
Name: CPU
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
Master station.
Support DB A20 AnyWire system.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability Q25HCPU PDF.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.8 channel.
Input: DC0~20mA Q25HCPU
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000.
Conversion speed: 80 s/1 channel.
18 point terminal station.Input voltage range: AC100-240V.
Output voltage: DC5V Q25HCPU PDF.
Output power: 8.5A.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q25HCPU PDF.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery MITSUBISHI Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion MITSUBISHI Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components, more convenient to create the program MITSUBISHI Programming Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.Output points: 16 points.
Output voltage and current: DC12~24V; 0.5A/ point; 4A common.
OFF leakage current: 0.1mA.
Response time: 1ms.
16 points and 1 common ends.
Leaky type.
18 point terminal station.
With the surge absorber.
With fuse.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the hiigh speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming Q25HCPU Manual.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module Q25HCPU Programming Manual.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed Q25HCPU Manual.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
Programmable logic controller CPU
R16CPU
MITSUBISHI Programmable logic controller CPU R16CPU
Operation control mode: stored procedure
MITSUBISHI
CPU unit
A3VCPU
MITSUBISHI CPU unit A3VCPU
Multiple CPU units for A3VTS multiplex s
MITSUBISHI
Sports CPU module (old model)
Q173CPU
MITSUBISHI Sports CPU module (old model) Q173CPU
Control axis: maximum 8 axes. Greater fl