MITSUBISHI Q12HCPU Programming Manual (Common Instruction 1/2) PDF
Product model: Q12HCPU
Name: PLC
Brand: MITSUBISHI
Sort: Common Instruction 1/2 Programming Manual
File language: English
Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 26 K step.
Processing speed: 79ns.
Program memory capacity: 144 KB Q12HCPU PDF.
Built in RS232 communication port.
Support installed memory card.
For A mode only.
Enhance the basic performance.
CPU''s built-in soft element memory capacity increases to up to 60K.
To increase the control, quality management data can also be processed at high speed Q12HCPU
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming Q12HCPU PDF.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying thee programming Q12HCPU Manual.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area Q12HCPU PDF.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved MITSUBISHI Programming Manual.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.Axis of control: 16.
Compact Q170MCPU integrated power supply module, PLC and motion controller,
And built in the packaging equipment used in the incremental synchronous encoder signal and signal detection signal required for the interface,
Do not need to add the appropriate module MITSUBISHI Programming Manual.
Other multi CPU platform, the need to do a lot of type of configuration in order to ensure the movement of CPU and CPU PLC normal communication,
This will cost engineers a lot of valuable time MITSUBISHI Programming Manual Q12HCPU Programming Manual.
This thorny problem is solved by the seamless integration of the Q170MCPU and the perfect combination of sequential conntrol and motion control Q12HCPU Manual.
Therefore, simply to carry out a simple set of multiple CPU to start the system, and the subsequent programming and debugging.
Related products
MITSUBISHI
Process CPU
Q12PRHCPU
MITSUBISHI Process CPU Q12PRHCPU
Program capacity: 124 K step. Input / ou
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Inp
MITSUBISHI
Programmable logic controller CPU
R16ENCPU
MITSUBISHI Programmable logic controller CPU R16ENCPU
Operation control mode: stored procedure