MITSUBISHI FR-F740-0.75K-CHT TECHNICAL MANUAL PDF
Product model: FR-F740-0.75K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: TECHNICAL MANUAL
File language: English
Protocol: SLMP, TCP/IP, UDP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Connect PLC FX3U/FX3UC to Ethernet FR-F740-0.75K-CHT PDF.
Support fixed buffer storage, communication connection MELSOFT, through the MC communication protocol, e-mail messages.
When connected to the MELSOFT, through the Works2 PLC can achieve the remote maintenance of GX program FR-F740-0.75K-CHT
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-F740-0.75K-CHT PDF.
Starting with power frequenccy power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FR-F740-0 FR-F740-0.75K-CHT Manual . 75K-CHT PDF.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load MITSUBISHI TECHNICAL MANUAL. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 22kw.
SLD converter rated current: 125A.
Structure and function: Standard model MITSUBISHI TECHNICAL MANUAL.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) MITSUBISHI TECHNICAL MANUAL FR-F740-0.75K-CHT TECHNICAL MANUAL.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FR-F740-0.75K-CHT Manual .
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.
Related products
MITSUBISHI
3 phase 400V converter
FR-F740-S160K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-S160K-CHT
MITSUBISHI inverter FR-F740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-F740-S630K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-S630K-CHT
MITSUBISHI inverter FR-F740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-F740-S400K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-S400K-CHT
MITSUBISHI inverter FR-F740 series. Volt
MITSUBISHI
Three phase 400V level inverter
IS74-0.75K-CHT
MITSUBISHI Three phase 400V level inverter IS74-0.75K-CHT
Applicale motor capacity: 0.75KW. Rated