LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
MITSUBISHI A956GOT-LBD User's Manual (Hardware) PDF
Product model: A956GOT-LBD
Name: touch screen
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA A956GOT-LBD PDF.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 3 line /2 line type.
Spring clip terminal A956GOT-LBD
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A956GOT-LBD PDF.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. RS-422 1 channel, RS-422/485 1 channel.
Transmission speed: 2 channel total is 115.2kbps.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment A956GOT-LBD PDF.
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharing concept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few MITSUBISHI User's Manual.
And MELSECNET/H not only inherited the excellent characteristics of MELSECNET/10,
Also makes the nettwork real-time better, more data capacity,
Further adapt to the needs of the market MITSUBISHI User's Manual A956GOT-LBD Manual. 2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Cannot extend.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI User's Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accordding to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A956GOT-LBD User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A956GOT-LBD Manual.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
6 inch man machine interface
A950GOT-LBD
MITSUBISHI 6 inch man machine interface A950GOT-LBD
Series Name: A950GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A953GOT-LBD
MITSUBISHI 6 inch man machine interface A953GOT-LBD
Series Name: A953GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A956GOT-SBD
MITSUBISHI 6 inch man machine interface A956GOT-SBD
Series Name: A956GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A956GOT-LBD
MITSUBISHI 6 inch man machine interface A956GOT-LBD
Series Name: A956GOT. Size: 6 inches. Re