MITSUBISHI A2ASCPU User's Manual PDF
Product model: A2ASCPU
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
QCPU (Q mode) bus connection.
2 joint.
Applicable models: A985 (-V) /975/970/960GOT. Adapter for mounting rails. Unit connection CPU unit.Input type: DC input, positive common end A2ASCPU PDF.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring A2ASCPU
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting A2ASCPU PDF.
Can be used for the 3 wire sensor input wiring A2ASCPU Manual . CC-Link master / slave station.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work A2ASCPU PDF MITSUBISHI User's Manual.
PLC is the use of " sequential scanning, and constantly circulating " way to work MITSUBISHI User's Manual.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodiic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in tthe process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI User's Manual A2ASCPU Manual A2ASCPU User's Manual.
Related products
MITSUBISHI
Motion controller
Q172DSCPU
MITSUBISHI Motion controller Q172DSCPU
Control axis: up to 16 axes. Servo ampli
MITSUBISHI
CPU unit
A2SCPU
MITSUBISHI CPU unit A2SCPU
Program memory capacity 14K. Input and o
MITSUBISHI
CPU unit
Q2ACPU
MITSUBISHI CPU unit Q2ACPU
Input and output points: 512 points. Inp