MR-J3-40A servo format
Time: 9/3/2017 1:00:14 PM

With commtion MR-J3-40A RS485 MR-J3-40A communication, modify the PA09 parameter for 21, station number is 1H, how to write it??
Re:   Time: 9/4/2017 4:20:00 AM
SOH station number instruction, STX data, No data, ETX check, 01H, 31H, 38H35H, 02H, PA-09 (...) 32H, 31H, 33H (sum)
Re:Re:   Time: 9/4/2017 6:44:00 AM
Please write 0130383502303030, 303030034332 (85 instructions, specify the PA parameter) first
Then assign the PA09 number parameters, 0130383402303130, 3030303030303903, and checksum.
Thank you
Welcome to call 400-- free technology hotline to get further related skills
Re:Re:Re:   Time: 9/4/2017 11:32:00 AM
Thank you Study! If I had 20 J3 servos, wouldn't that be one by one?
Re:Re:Re:Re:   Time: 9/4/2017 1:56:00 PM
Yes, communication can only be sent one by one.
Thank you

Re:Re:Re:Re:Re:   Time: 9/4/2017 6:44:00 PM
Thank you Study!