How to use the M70 system call subroutine CF card
Time: 5/31/2017 10:12:20 PM

Hello I would M70 system like M70 system to ask how to call in the M70 system in the CF card I use CF subroutine call subroutine p232 alarm processing time
Ask for help
Thanks
Re:   Time: 6/1/2017 1:28:00 AM
Calling the program in the IC card can use the M198 P*** command, where * * * stands for the program number in your IC card
Re:Re:   Time: 6/1/2017 3:52:00 AM
The main program is in memory, or CF card, in addition, CF card and IC card in the subroutine call subroutine calls are the same?
Re:Re:Re:   Time: 6/1/2017 8:40:00 AM
Call the CF card in the program, need to use M198 P****. At the same time, the program that calls memory uses M98 P****. If the CF card or memory program with letters, need to use M98<****> or M198<****> call. Such as M98<5.NC>