LK Automation Limited LK Automation Limited
Problem sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Problems
MITSUBISHI communication module QJ71C24N-R2
Time: 2017/9/5 19:10:56

How can MISHI QJ71C24N-R2 communication QJ71C24N-R2 module be used? QPLC CPU Q06H QJ71C24N-R2 PRo-face communication module is GP2501 series, problems of the old equipment after moving machine,
The communication line has no problem, and PRe-face touch screen communication, re232c interface (CH2), baud rate 57600, parity check, 7 bit data bit, 2 bit stop bit, DTR/ERR; GX software is set to CH1:AD2 004; CH2:A7C 004
present
Re:   Time: 2017/9/6 2:48:00
RD, SD lights represent data transmission. Please make sure the error code is on when you press the button. Check in the diagnostics system monitor.
Re:Re:   Time: 2017/9/6 5:12:00
The error code is 7h68, or 7h69
Re:Re:Re:   Time: 2017/9/6 10:00:00
Are you 7F68 and 7F69?

Re:Re:Re:Re:   Time: 2017/9/6 12:24:00
It's 7F68 and 7F69
Re:Re:Re:Re:Re:   Time: 2017/9/6 17:12:00
Hello, 7F68 and 7F69 are caused by interference on the line.