OMRON C500-IA222 C500-IA222


Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point C500-IA222.
Externa connection, Removable erminal block.
Currrent consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data C500-IA222.
Analog Output Units for converting ,
binary data into analog output signals. Model : CV500-TDL21.
You can connect up to 64 at a temperature controller using two communication ports..
Connects Power Supply Adapter and SYSMAC NET Link Unit C500-IA222.
Included with C200H-APS02.Protector for Simple Expansion I/O Rack connector CV500-COV04Model: C200H-AD001.
Input points: 4.
Voltage input: 1 to 5V or 0 to 10 V.
Current input: 4 to 20 mA.Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output OMRON C500-IA222.
Signal range, Resolution: 1 to 5V(1/10,000),
0 to 10V(1/20,000), and -10 to 10V(1/40,000).
Conversion period: 20 μs/ 1 point,
25 μs/ 2 points, 30 μs/ 3 points,
35 μs/ 4 points The Direct conver sion is provided OMRON C500-IA222.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: --.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.40A; 24V, --.
Standards: UC1, CE OMRON C500-IA222.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C500-IA222.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.