SRT2-OD16T Transistor Remote I/O Terminals with 3-tier Terminal Block OMRON SRT2-OD16T


Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 48 V.
Output current: 1.1 A.
Built-in fan: No SRT2-OD16T.
Easy-to-use, Widely range from 15 W to 600 W (Output VVoltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models) SRT2-OD16T.
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply SRT2-OD16T.).Type: open type.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 12V.
Output current: 8 OMRON SRT2-OD16T.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity OMRON SRT2-OD16T.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock OMRON SRT2-OD16T.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)

I/O classification: Digital output.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuratiion, Input Points,
I/O Points, or Output Points SRT2-OD16T.
Incorporates easy-to-wire terminals each,
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction.