"The length of the cable: 3 meters.
IQ-R MELSEC series of "inter module synchronization", refers to the module can be in accordance with the synchronization cycle between modules,
The function of the input and output time synchronization of the multiple input and output modules and the intelligent function modules of the synchronization object R120ENCPU.
Using thhis function, the system and equipment can be controlled with high precision.
In addition, it is also available in the CC-LinkIE field network synchronous communication, so that the action time between the network nodes to maintain synchronization,
To avoid the error caused by the network transmission delay time, so as to build a stable system R120ENCPU.
At the same time using these features, it can be easy to respond to the requirements of the high accuracy of the movement of the situation,
For example, the cutting and bending process of offset press, etc R120ENCPU MITSUBISHI R120ENCPU.. "DC input, transistor (source) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): 2 ~ 5mA DC5/12/24V MITSUBISHI R120ENCPU.
Pulse measurement function can be measured by measuring the pulse ON/OFF time and cycle, the length and speed of the workpiece MITSUBISHI R120ENCPU.
For example, in the production of food, beverages, the use of proximity sensors to measure the size and speed of the bottle on the conveyor. Main base plate, extended substrate mounting.1Gbps, master / local station.
IE Field CC-Link network is a kind of field network based on Gigabit Ethernet,
Integrated control of the controller, I/O control, safety control, motion control, can carry out a full range of control.
According to the production line, equipment, equipment layout, the star, linear and ring topology of flexible wiring.
Building a flexible network
Star topology
Star connection is carried out among the modules by using switching hubs.
When using star topology, you can easily add from the station.
Linear topology
Between the modules to carry out a linear connection.
Distribution cost can be reduced.
Ring topology
Ring connection in between each module.
Part of the anomaly occurs from the station, can be through the ring back function,
Use only normal station to continue data link.
Support IE Field CC-Link network synchronous communication function
According to the synchronization period specified by the master station, the control period of the slave station is synchronized by the IE Field CC-Link network R120ENCPU.
According to this, the action time of the station can be synchronized with other slave stations which are connected on the same network.