OMRON CS1W-AD161 OMRON CS1W-AD161


Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
Units cannot be mounted; 10 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes CS1W-AD161.
Special I/O Units: CS-series Special I/O Unit,
Yes; C2200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, -- CS1W-AD161.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Model: C500-CT021.
2 pts.
50kcps 7 mode.
Unit type: CS-series Special I/O Units.
Product name: Analog Input Units CS1W-AD161.
Specifications: I/O points, 16 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max.
(Settable to 1 ms/point) OMRON CS1W-AD161.
Externa connection, MIL connector.
Current consumption: 5V, 0.15A; 26V, 0.06A.
Standards: UC1, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals OMRON CS1W-AD161. CPU Unit: CP1L-M CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 24; Output, 16 OMRON CS1W-AD161.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Required for Analog Input and Output Units: For two Analog Units.Name: Analog I/O Slave Units,
(Numerical indicator type)
MIL Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1W-AD161.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.