LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
MR-J3-DU55KB4 | MITSUBISHI SSCNET type III optical fiber communication driver MR-J3-DU55KB4


The length of the line: 2M.
IP level: IP65.
Cable outlet direction: the same side of the motor shaft.
Bending life: high bending life.
Encoder with cable (motor side); for HF-KP/HF-MP series (motor shaft with side extraction). MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series MR-J3-DU55KB4.
Rated output: 15.0kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: three phase AC400V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier MR-J3-DU55KB4.
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed MITSUBISHI MR-J3-DU55KB4.
SS1 functions can be realized by using the MR-J3-D05 security logic unit MR-J3-DU55KB4.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS MITSUBISHI MR-J3-DU55KB4.
Security functions are connected to the CN8 interface through an external security circuit to increase the MR-J3-BS driver security.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version MITSUBISHI MR-J3-DU55KB4. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 2.0kw.
Interface type: SSCNET type III fiber communication.
Special specification: suitable for linear servo motor.
Power specification: three phase AC200V.
More advanced real-time automatic tuning by setting response values,
Including the position gain and the gain of speed, all the gain can be adjusted automatically.
32 segment response level can be set.
Advanced vibration suppression control.
An optimal vibration control filter value is automatically set by the automatic tuning function to effecctively suppress the vibration of the 100Hz frequency that occurs when the driving part stops MR-J3-DU55KB4.
The automatic tuning function can effectively restrain the vibration of the end of the mechanical arm and reduce the residual vibration in the machine.

Related supply information