Program capacity: 28K step.
Input / output points: 1096 points.
Number of input and output elements: 8192.
Processing speed: 0.034 subtle.
Support RS232.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register QJ71GF11-T2.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time QJ71GF11-T2.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias QJ71GF11-T2.Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI QJ71GF11-T2.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI QJ71GF11-T2.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module MITSUBISHI QJ71GF11-T2.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Workks2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation QJ71GF11-T2.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.