DRT2-OD16 Transistor Remote I/O Terminals OMRON DRT2-OD16


Release key type: Trapped key *1.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring pattterns DRT2-OD16.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas DRT2-OD16.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; M20 DRT2-OD16.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement OMRON DRT2-OD16.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Specifications: Outputs; NPN (- common); 16 points OMRON DRT2-OD16.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system OMRON DRT2-OD16.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Ratings: 1 A at 125 VAC.
LED indicator: With indicator.
Actuator: Sealed roller plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP667 degree of protection DRT2-OD16.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.)