LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
CS1W-PDC55 OMRON CS1W-PDC55 Process Analog I/O Units


Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CS1W-PDC55.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block CS1W-PDC55.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V) CS1W-PDC55.
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.
Unit classification: CJ1 Special I/O Units.
name: Position control unit OMRON CS1W-PDC55.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Line-driver output;
Number of control axes : 2 axes.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE OMRON CS1W-PDC55.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control OMRON CS1W-PDC55.

Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CS1W-PDC55.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information