CQM1-ID214 OMRON CQM1-ID214 Input Voltage: 24V DC DC Input Module


Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000) CQM1-ID214.
Conversion period: 1 ms/pointt,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F CQM1-ID214.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup CQM1-ID214.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. ASCII Unit
This program runs independently from the ladder-diagram program in the PLC OMRON CQM1-ID214.

Name: ASCII Module.
Model: C200H-ASC31.
Communications port>Port 1: RS-232C(peripheral device connec-tion).
Communications port>Port 2: RS-232C(peripheral device connec-ti
Number of inputs: 32 pts.
Input Voltage: 24V DC OMRON CQM1-ID214.
Input Current: 4 mA.Number of outputs: 8 pts.
Max. switch-ing capacity: 1.0 A at 24 V DC.
External connector: Terminal block.
Weight: 240 g max.Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point OMRON CQM1-ID214.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.20A; 26V, 0.20A.
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CQM1-ID214.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information