LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
CJ1W-OC211 OMRON Output Units CJ1W-OC211


Unit type: CJ1 CPU Bus Unit.
Product Name: Ethernet Unit.
Specifications:Communications cable,
100Base-TX; Communications functions,
FINS communications service(TCP/IP, UDP/IP),
FTP server functions, socket services,
mail transmission service,
mail reception (remote command receive),
automatic adjustment of PLC''s built-in clock, server/host name specifications;
nits per CPU Unit: 4 CJ1W-OC211.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0 CJ1W-OC211.37A; 24V,--.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Management Select the required,
communications services according to,
application needs to flexibly integrate,
PLCs with an Ethernet information network. Unit type: CS1 Special I/O Units CJ1W-OC211.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs OMRON CJ1W-OC211.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON CJ1W-OC211.
Because of this, no ladder program is required,
at the CPU Unit for scaling OMRON CJ1W-OC211.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
Unit type: CJ1 Basic I/O Units.
Product name: Relay Contact Output Units.
Specifications: Output type , --;
I/O points, 16 inputs;
Maximum switching capacity, 250VAC/24VDC, 2A;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.11A; 24V, 0.096A max.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Unitts receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CJ1W-OC211.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
 

Related supply information