LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
C500-LK103-P OMRON C500-LK103-P


Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming,
I/O communications: 64 nodes;
No C500-LK103-P. of axes: 4 axxes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency C500-LK103-P.
The EtherCAT communications with,
100Mbps baud rate enables fast,
and accurate position control.
A wide range of position control,
functions are available with,
this position control unit C500-LK103-P.
Model : C500-LK103-P.
APF/ PCF.Name: Compact Connectors.
Specifications: Inputs/Outputs; 1 input/1 output; PNP.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit OMRON C500-LK103-P.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price OMRON C500-LK103-P.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input OMRON C500-LK103-P.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C500-LK103-P.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information