C200H-ID218 No of points: 32 pts OMRON C200H-ID218 DC High-density Input Module


Unit type: CJ1 Basic I/O Units.
Product name: AC Input Units.
Specifications: I/O points, 8 inputs;
Input voltage and current: 200 to 24 VAC, 10 mA(200V, 50Hz);
Commons, 8 points, 1 common; External connection,
Removable Terminal Block; No. of words allocated, 1 word C200H-ID218.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.<
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit C200H-ID218.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Output method: Transistor sourcing.
Inputs: ---.
Outputs: 8 C200H-ID218.
Model: C200H-ID218.
No. of points: 32 pts.
Specifications: 24 VDC.
Weight: 180g max.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks)Unit type: CJ1 Special I/O Units OMRON C200H-ID218.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000) OMRON C200H-ID218.
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block OMRON C200H-ID218.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-E.Specifications: 4 Kwords without clock.C500-OD I/O Unit Transistor Output 16 pts C500-OD411(3G2A5-OD411).
DC12~48V 1A.Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(only 1 axis for 5 V or 12 V input),
RS-422 line driver;
Max. counting rate, 50kHz, 500kHz.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
tto 500 kHz allows precise control of fast motions C200H-ID218.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications.