3G2A5-OC221 OMRON 3G2A5-OC221


Coaxial.Specification: three phase 400V.
Power: 1.5KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling: forced air cooling.
Weight: 1.2kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of tthe inverter --3G3MZ 3G2A5-OC221.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G2A5-OC221.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice 3G2A5-OC221.
Specification: three phase 400V.
Power: 185KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380 OMRON 3G2A5-OC221.
Weight: about 260kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact OMRON 3G2A5-OC221.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function OMRON 3G2A5-OC221.
Colorful function.
Brake transistor built-in.
Protection function. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 2 square mm, 3.5 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Inverter input power: 3 phase / single phase AC200V.
Weight: 0.8KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Born to drive machines.
Positioning functionality.
Fieldbus communications with optional unit,
EtherCAT, CompoNet and DeviceNet,
Drive Programming.
Current vector Control.
High Starting torque: 200% at 0.5 Hz.
Safety function * EN ISO 13849-1:2008 (Cat.3/PLd),
> IEC 60204-1 Stop Category 0,
Speed range up to 580 Hz 3G2A5-OC221.
When optional DeviceNet communication unit or CompoNet communication unit is,
mounted onto the MX2-series V1 type, the inverter will not conform to the safety,
standards.