3G2A5-IA222 OMRON 3G2A5-IA222


Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 5.5 square mm.
Weight: 0.8kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Function name: 3 phase 200V 3G2A5-IA222.
Power: 1.5KW.
Maximum output voltage: three phase 200 ~ 240VAAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling: forced cooling.
Weight: 1 3G2A5-IA222.2kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver 3G2A5-IA222.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control OMRON 3G2A5-IA222.
Function name: single phase 200V.
Power: 0.1KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68 OMRON 3G2A5-IA222.
Outline dimension (deep):109mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0 OMRON 3G2A5-IA222.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.0KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Born to drive machines.
Positioning functionality.
Fieldbus communications with optional unit,
EtherCAT, CompoNet and DeviceNet,
Drive Programming.
Current vector Control.
High Starting torque: 200% at 0.5 Hz.
Safety function * EN ISO 13849-1:2008 (Cat.3/PLd),
> IEC 60204-1 Stop Category 0,
Speed range up to 580 Hz 3G2A5-IA222.
When optional DeviceNet communication unit or CompoNet communication unit is,
mounted onto the MX2-series V1 type, the inverter will not conform to the safety,
standards.