LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON S8VM-10024A Installation and Operating Manual PDF
Product model: S8VM-10024A
Name: Digital Controller
Brand: OMRON
Sort: Installation and Operating Manual
File language: English
Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 150W.
Output voltage: 5V S8VM-10024A PDF.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function S8VM-10024A
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products S8VM-10024A PDF.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No S8VM-10024A PDF. 14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Appearance: insert type.
Control supply voltage: DC48V OMRON Installation and Operating Manual.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for sinngle phase motor over current protection S8VM-10024A Manual.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc OMRON Installation and Operating Manual. , are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple OMRON Installation and Operating Manual.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple. Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 5 A.
Alarm output *2: --.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output sstandards S8VM-10024A Installation and Operating Manual.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8VM-10024A Manual.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
Related products
OMRON
Switching Mode Power Supply
S8VM-10024C
OMRON Switching Mode Power Supply S8VM-10024C
Category: incidental cover type. Structu
OMRON
Switching Mode Power Supply
S8VM-10015D
OMRON Switching Mode Power Supply S8VM-10015D
Type: open type. Structure: DIN guide ra
OMRON
Switching Mode Power Supply
S8VM-10012
OMRON Switching Mode Power Supply S8VM-10012
Type: open type. Structure: ottom mount
OMRON
Switching Mode Power Supply
S8VM-01515CD
OMRON Switching Mode Power Supply S8VM-01515CD
Category: incidental cover type. Structu