LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON S8T-DCBU-02 EtherNet/IP Connection Guide PDF
Product model: S8T-DCBU-02
Name: Digital Controller
Brand: OMRON
Sort: EtherNet/IP Connection Guide
File language: English
Power ratings: 150 W.
Output voltage: 48 V.
Output current: 3.2 A.
Boost current: 6.4 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup S8T-DCBU-02 PDF.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output S8T-DCBU-02
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC S8T-DCBU-02 PDF.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Control power supply voltage: 48 VDC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V S8T-DCBU-02 PDF.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC ccircuits using shunt (SDV-FL) S8T-DCBU-02 Manual.
Detect three-phase AC current for under and/or overcur,
rent using current converter OMRON EtherNet/IP Connection Guide.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection OMRON EtherNet/IP Connection Guide.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input OMRON EtherNet/IP Connection Guide. ).
Power ratings: 50 W.
Output voltage: 12 V.
Output current: 4.2 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 5008/60950-1, cUL CSA C22 S8T-DCBU-02 EtherNet/IP Connection Guide. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply S8T-DCBU-02 Manual. ).
Related products
OMRON
Buffer Block
S8T-DCBU-02 Series
OMRON Buffer Block S8T-DCBU-02 Series
Prevents Equipment Stoppage, Data Loss,
OMRON
DC Backup Block for S8TS
S8T-DCBU-01 Series
OMRON DC Backup Block for S8TS S8T-DCBU-01 Series
DC Backup Block for S8TS Prevents 24-VDC
OMRON
Buffer Block
S8T-DCBU-02
OMRON Buffer Block S8T-DCBU-02
Input voltage: 24 VDC 24 to 28 VDC. O
OMRON
DC Backup Block for S8TS
S8T-DCBU-01
OMRON DC Backup Block for S8TS S8T-DCBU-01
Input voltage: 24 to 28 VDC. Output vol