OMRON K8AB-TH11S User's Manual PDF
Product model: K8AB-TH11S
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) K8AB-TH11S PDF.
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-TH11S
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K8AB-TH11S PDF.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be seet separately for CT1 and CT2 K8AB-TH11S PDF K8AB-TH11S Manual.
CE marking and cUL certified (K8AC-H2@@@). Rated primary current: 200 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power OMRON User's Manual.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit OMRON User's Manual.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power OMRON User's Manual.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped powerr K8AB-TH11S User's Manual. )
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss K8AB-TH11S Manual.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
Related products
OMRON
Single-phase Voltage Relay
K8AB-VS1 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS1 AC200/230V
Measuring voltage: 6 to 60 mV AC/DC, 10
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VW2 AC200/230V
Measuring voltage: 1 to 10 V AC/DC, 3 to
OMRON
Temperature Monitoring Relay
K8AB-TH11S AC100-240
OMRON Temperature Monitoring Relay K8AB-TH11S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm. Suppl
OMRON
Single-phase Current Relay
K8AB-AS Series
OMRON Single-phase Current Relay K8AB-AS Series
Ideal for current monitoring for, indus