OMRON K3HB-XVD-FLK3AT11 Communications Manual PDF
Product model: K3HB-XVD-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA K3HB-XVD-FLK3AT11 PDF.
BCD+ transistor: -; NPN open collector (5 digit output +OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter K3HB-XVD-FLK3AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse isRated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC K3HB-XVD-FLK3AT11 PDF.
Ideaal for Monitoring 3-phase Power Supplies K3HB-XVD-FLK3AT11 Manual.
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, phase sequence, and phase loss in three,
phase three-wire circuits with one unit K3HB-XVD-FLK3AT11 PDF.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control OMRON Communications Manual.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON Communications Manual.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
Hiigh-precision heater burnout alarm with digital measurement OMRON Communications Manual K3HB-XVD-FLK3AT11 Communications Manual.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-XVD-FLK3AT11 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).