OMRON K3HB-XVA-FLK3AT11 Communications Manual PDF
Product model: K3HB-XVA-FLK3AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-XVA-FLK3AT11 PDF.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XVA-FLK3AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-XVA-FLK3AT11 PDF.
External eventsControl supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Acccurate Detection of Heater Element K3HB-XVA-FLK3AT11 Manual.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-XVA-FLK3AT11 PDF.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters OMRON Communications Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Protect motors and other equipment from unstable,
voltages in the power supply system.
Protect motors and other equipment by detecting,
phase sequence and phase loss for three-phase,
power supplies OMRON Communications Manual.
Phase loss detection while the motor is operating.
Global application with power supply range of 200 to 480 V with one Relay.
Greater resistance to inverter noise.
Width of 17.5 mm to reduce space required in ppanels OMRON Communications Manual K3HB-XVA-FLK3AT11 Communications Manual.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed ffor easy shipping to North America K3HB-XVA-FLK3AT11 Manual.
Certification is pending for LR standards.
Models added with transistor outputs for superior contact reliability.