OMRON K3HB-VLC-L2ET11 User's Manual PDF
Product model: K3HB-VLC-L2ET11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-VLC-L2ET11 PDF.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-L2ET11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-VLC-L2ET11 PDF.
External event input can be applied to a variety of measurement and identification situations. Power supply voltage: 24 VAC/DC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment.
Self-holding circuit implemented with circuit processing that is,
not depending on external wiring K3HB-VLC-L2ET11 PDF.
Switch between water supply and discharge with a DIP switch setting.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids.
Prevents chattering of relay contacts that occurs with ripples.
Easy wiring with ferrules OMRON User's Manual.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch. Type of input: AC voltage input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V OMRONN User's Manual K3HB-VLC-L2ET11 Manual.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON User's Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemTime specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K3HB-VLC-L2ET11 User's Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-L2ET11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.